Product Introduction
Category:
TOF sensor
• Stable long-distance detection
• Measuring long-distance products using the principles of light propagation
• The light spot at 2 meters is less than 5 mm.
- Product Details
- Specification Parameters
- External dimensions
-
I. Ultra-high detection performance
The detection principle of the JP-D60 series is based on measuring the distance traveled by pulsed laser light as it is emitted, reflected off an object, and returns. This method is unaffected by the surface condition of the workpiece, enabling stable detection.

II. Accurate and Simple Setup
Relying on a clear and straightforward OLED display and a combination of three buttons to adjust various parameters and operating modes.


The OLED display can accurately show characters; simply observe the screen to operate it. The red light stays on continuously when power is applied and no output is present; the blue light stays on continuously and provides a stable output when the set conditions are met. III. Ultra-long-distance Detection and Installation
The work area is fraught with numerous complexities, and occasionally sensors may collide with workpieces during installation, leading to detection failures. However, the JP-D60 series can be installed in undisturbed locations, enabling “ultra-long-distance setting and detection” and thereby avoiding collisions and overlapping positions that could otherwise affect operations.


Standard optoelectronic installation requires a very close distance. TOF sensors can be installed in remote locations for detection. IV. Example of Robotic Arm Handling
There are numerous risks associated with the operation of robotic arms in their vicinity. For instance, an improperly positioned chuck could lead to collisions between tools and sensors, or false detections caused by splashes of liquids from workpieces adhering to the surface—both of which can damage the sensors. However, the JP-D60 series’ “ultra-long-distance installation and detection” feature effectively avoids collisions, water splashes, and unintended movements that might be triggered by robotic arm handling, thereby ensuring smooth and uninterrupted production operations.


Application scenarios 


Robotic Arm Applications Detect object height Barn height 


Automotive assembly Logistics system Photovoltaic equipment -
Name TOF sensor Model JP-D60 JP-D60P Output mode NPN PNP Switch type IO output (normally open/normally closed) Measurement range 40 to 2000 mm Output frame rate 100Hz Light source type Red Light Class 2 [EN/IEC] Laser power ≤1.0 mW Wavelength 650-700nm Power supply voltage 12-24V DC Current consumption <150mA Control output The applied voltage is 24 VDC or less.
Control the current below 100mA.
Control the current below 100mA. Baud rate 9600 / 19200 / 115200 bps Communication method 485 communication Launch angle ±0.5 degrees Repeatability 5mm Protection circuit Power reverse connection protection, power surge protection/output short-circuit protection, output reverse connection protection, output surge protection, 485 short-circuit protection Display Power indicator Red light Operation status Blue light Numerical display OLED display Connection method 6-core insulated cable, 2m Ambient lighting Incandescent lamps: below 10,000 lux Enclosure protection class IP67 Environmental resistance Operating temperature -20 to +60°C Maximum resistance to external light 10 klx; (on the object) Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y, and Z directions. Materials Housing: Aluminum alloy; Display cover: Acrylic transparent; Lens: Glass; Indicator light cover: TPU Weight (with 2-meter cable) About 73 grams Other parameters Accuracy Black (6% reflectance) White (90% reflectance) Distance 0mm ±15 mm ±15 mm 500mm ±15 mm ±15 mm 1000mm ±15 mm ±15 mm 1500mm ±20 mm ±20 mm 2000mm ±30 mm ±20 mm Name TOF sensor Model JP-D100 Output mode NPN Switch type IO output (normally open) Measurement principle Phase Measurement range 100m Output frame rate Supports single-measurement and continuous-measurement modes; continuous-measurement frequencies of 5 Hz, 10 Hz, 20 Hz, and 30 Hz are optional. Spot size 7 mm (at 10 m) Light source type Red Laser Class II Laser power ≤0.95 mW Wavelength 650~660 nm Power supply voltage 12-24V DC Current consumption <150mA Control output The applied voltage is below 24 VDC, and the control current is below 100 mA. Communication method RS485, CAN, 2-channel digital output Repeatability ±1.5 mm (diffuse reflection, <20 m) ±3.0 mm (full range) Protection circuit Power reverse connection protection, power surge protection/output short-circuit protection, output reverse connection protection, output surge protection Display Power indicator Red Operation status Orange Numerical display Green Connection method M12 connector, with an M12-12-core female straight-head 200mm cable. Enclosure protection rating IP65 Environmental resistance Operating temperature -20 to +60°C Maximum resistance to external light 10 klx; (on the object) Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y, and Z directions. Shell material Aluminum alloy Weight 383 g (including cable) -
Model: JP-D60/JP-D60P

Model: JP-D100

Keywords: