Product Introduction
Category:
Optical fiber amplifier
• One-click preset
• Automatic maintenance
• Simple and convenient
- Product Details
- Specification Parameters
- External dimensions
-
1. Simply complete the setup with one click.
By performing a simple operation, you can adjust the current value to “100.0” while setting the sensitivity. This eliminates biases caused by differences in detection content and individual variations, thereby helping to prevent and maintain quality.

● Long press 【PRESET】 to cancel.
● Cannot be used in conjunction with zero-point migration.
Press the [PRESET] button once.

II. Maximum Sensitivity Calibration
This sensitivity-setting method is suitable for situations where dust or dirt can reduce the intensity of the received light. Calibrate the set value to be slightly lower than the determined received light intensity.
Through-beam type: Workpiece present Reflective type: No workpiece


Press and hold the SET key for 3 seconds or longer until “SET” starts flashing, then release. 
When using a reflective-type device with no workpiece present, or when using a contrast-type / retroreflective-type device with a workpiece present, press and hold the [SET] button for more than three seconds.
When the “SET” light is flashing, release the button. The set value will flash immediately, indicating that calibration is complete and then the light will turn steady (on). Press the button to adjust the set value.
Product Selection 

-
Model JF-21 Type Standard 1-way output
Cable
Output type NPN Main unit/Expansion unit Main module (non-expandable) Control output 1st output
NPN collector open-circuit, 24V or less, maximum current 100mA or less, residual voltage 1V or less.
External input None Output switching Light-ON/Dark-ON Switch Light source Red LED (wavelength: 660 nm) Timer function Timer off, delay disconnect, delay enable, single shot Response time 50μs (HIGH SPEED) / 250μs (FINE) / 500μs (TURBO) / 1ms (SUPER) / 4ms (ULTRA) / 16ms (MEGA) Number of anti-interference units 0 units (does not support interference prevention function) Housing dimensions 29.6mm (H) × 10.8mm (W) × 83.1mm (L) Protection circuit Reverse power connection protection, output power protection, and output surge protection Rated Power supply voltage 12 to 24 VDC ±10%, ripple (P-P) below 10% Current consumption Normal: Up to 630 mW (at 24 V, up to 26 mA; at 12 V, up to 34 mA)
Energy-saving mode (ALL): Up to 560 mW (24 V, up to 23 mA; 12 V, up to 28 mA)
Full-energy-saving mode: Up to 380 mW (24 V, up to 15 mA; at 12 V, up to 19 mA)
Environmental resistance Ambient lighting Incandescent lamp: 20,000 lux or lower; fluorescent lamp: 30,000 lux or lower. Ambient temperature -20 to +55℃ (no freezing) Relative humidity 35% to 85% RH (no condensation) Seismic resistance 10 to 55 Hz, double amplitude of 1.5 mm, 2 hours each in the X, Y, and Z directions Impact resistance 500 m/s², 3 times each in the X, Y, and Z directions Housing material ABS+PC Weight Approximately 45g -