Product Introduction

Split-type laser ranging sensor
+
  • Split-type laser ranging sensor

Split-type laser ranging sensor

• Smaller in size, easy to operate
• Bus-compatible
• The matching controller is designed for complex environments.

  • Product Details
  • Specification Parameters
  • External dimensions
  •  

    1. Smaller volume

    The LS-D1 series is smaller in size compared to the LS-D2 series.

         

    II. The controller combination for complex environments

    For complex and confined environments, the LS-D1 series can be remotely controlled via a controller.

         

    3. Equipped with super-resolution algorithms

    Based on the surface condition of the target workpiece, the system automatically performs ideal waveform processing. Even for previously difficult-to-detect workpieces such as thin metal wires and resins, stable detection can be achieved without any adjustments.

         

    4. Configure the concave distance counting filter function.

    This feature automatically identifies the edges of recesses and outputs the measurement for each recess in a single operation. In applications such as counting and seam detection, simple setup can be completed without time-consuming effort.

    Step one   Step 2   Step 3
       
    Press the SET button on the side with the lower recess.   Press the SET button on the side with the higher concave distance.   Automatically enter the threshold at the median value.
             
    Calculate the number of printed materials.

     

    Application scenarios
       
    Measure the margin of functional films.   Workpiece Flatness Inspection   Check tire deviation.
             
       
    Detect the warpage of the substrate.   Confirm the arrangement of the packaging boxes.   Inspect the joints of the rubber sheet.
             

     

     

  •  

    Sensor
    Model   LS-D1-50A
    Probe structure   Split type
    Output   NPN
    High-precision measurement range Measurement range 25–50 mm
    Repeatability ±20 μm
    Other measurement ranges Measurement range 50–80 mm
    Repeatability ±50 μm
    Spot size   0.18 mm × 0.15 mm (at 50 mm)
    Response time   1ms/10ms/50ms switching mode
    Light source   Red Semiconductor Laser, Class 2 [JIS/IEC/GB/(FDA Note 2)] Maximum Output: 1.8 mW; Peak Emission Wavelength: 650 nm
    Power supply voltage   10–30 VDC, including 10% (p-p) ripple, Class 2 or LPS
    Power consumption   24V/40mA
    Control output   NPN collector open-circuit: When the external voltage is below 30 VDC, the control current is below 100 mA, the residual current is below 10 mA, and the residual voltage is below 1.2 V; when the current is between 10 and 100 mA, the residual voltage is below 2 V.
    Protection circuit   Power reverse connection protection, output overcurrent protection, output surge protection, output reverse connection protection
    Output action   Switching method: ON when light is detected / ON when light is blocked
    Enclosure protection rating   IP65
    Ambient lighting   Incandescent lamps: below 2000 lux; daylight: below 4000 lux.
    Ambient temperature   -10 to +50°C (no freezing)
    Storage environment temperature   -25 to +75°C (no freezing)
    Relative humidity   35% to 85% RH (no condensation)
    Impact resistance   6 times each in the X, Y, and Z directions at 1000 m/s²
    Vibration resistance   10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y, and Z directions
    Timer   OFF/ON - Delay/OFF - Delay/Single Pulse

     

    Controller
    Model   LS-DC1
    Installation method   DIN Rail Mounting Setup
    Communication method   RS-485
    Display Measured value · Set value Dot matrix display, 128 x 64 pixels, Chinese/English optional
    Indicator light

    Power indicator light: Red

    Communication indicator light: Green

    Output indicator: Orange

    I/O Digital output 2-channel output NPN
    Max. 100mA / DC 24V Residual voltage below 1.8V
    Rated value Power supply voltage DC 12~24V
    Current consumption 24V/20mA
    Environmental resistance Protection circuit Reverse polarity protection and overcurrent protection functions
    Protection level IEC rating IP50
    Operating temperature/humidity -20~+50℃ / 35~85% RH (no condensation or icing)
    Storage environment temperature/humidity -20~+60℃ / 35~85% RH (no condensation or ice formation)
    Anti-vibration 10–55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
    Impact-resistant 500 m/s² (approximately 50 G), 3 times in each of the X, Y, and Z directions
    Material   PC
    Quality   170g

     

  • Model: LS-D1-50A

     


     

    Model: LS-DC1

     

     

     

Keywords:

Sensor

Measurement sensor

Measuring instrument

Visual system

Communication

Product Inquiry

If you’re interested in our products, please leave us a message.

Submit
%{tishi_zhanwei}%