Product Introduction

Integrated laser ranging sensor
+
  • Integrated laser ranging sensor

Integrated laser ranging sensor

• Ultra-simplified body design
• Easier to operate
• Long service life

  • Product Details
  • Specification Parameters
  • External dimensions
  •  

    I. Detection Principle

    Triangulation is one of the detection principles used in displacement sensors. The light emitted by the transmitter illuminates the workpiece, and the reflected light is then captured by the receiver. Typically, by extending the optical path length between the illuminated area and the photosensitive element (CMOS), it’s possible to achieve higher-precision and more stable measurement results. However, on the other hand, this approach also increases the sensor’s depth dimension and leads to a larger overall body size. The LS-D series features a novel optical system equipped with internal mirrors, which shortens the sensor’s depth dimension while still delivering high-precision measurements comparable to those of displacement sensors.

     
         

    II. Robust body, IP67 protection rating

    It features an aluminum die-cast housing that simultaneously balances lightweight design with high strength. Despite its compact size, the body is remarkably robust, thereby minimizing the impact of external factors such as casing deformation and temperature fluctuations on measurement accuracy.

         

    3. Equipped with super-resolution algorithms

    Based on the surface condition of the target workpiece, the system automatically performs ideal waveform processing. Even for previously difficult-to-detect workpieces such as thin metal wires and resins, stable detection can be achieved without any adjustments.

         

    IV. New Mode with Thickness Calibration Function

     

    Step one   Step 2   Step 3
       
    Bring the sensor head of one side close to the workpiece, enter the thickness data, and press the SET button.   Bring the sensor head on the opposite side as close to the workpiece as in Step 1, then press the SET button.  

    Insert a workpiece that is thicker than the one used in Step 2, and enter the thickness data.

    Press the SET button to complete the calibration.

             

    5. Configure the concave distance counting filter function.

    This feature automatically identifies the edges of recesses and outputs the measurement for each recess in a single operation. In applications such as counting and seam detection, simple settings can be made without wasting time.

    Step one   Step 2   Step 3
       
    Press the SET button on the side with the lower recess.   Press the SET button on the side with the higher concave distance.   Automatically enter the threshold at the median value.
             
    Calculate the number of printed materials.

     

    Application scenarios
       
    Measure the amount of distortion in the iron ring material.   Check for the presence or absence of washers.   Check for the presence or absence of O-rings.
             
       
    Detection of Functional Film Interface (Overlap)   Determining the front and back sides of electronic component housings   Detecting overlap of lead frames
             
       
    Measure the plate thickness   Measure the insertion depth of the solenoid component.   Measure the thickness of the component.

     

     

  • Model   LS-D2-50A LS-D2-50AP
    Probe structure   Integrated
    Output   NPN PNP
    High-precision measurement range Measurement range 25–50 mm
    Repeatability ±20 μm
    Other measurement ranges Measurement range 50–80 mm
    Repeatability ±50 μm
    Spot size   0.18 mm × 0.15 mm (at 50 mm)
    Response time   1ms/10ms/50ms switching mode
    Light source   Red Semiconductor Laser, Class 2 [JIS/IEC/GB/(FDA Note 2)] Maximum Output: 1.8 mW; Peak Emission Wavelength: 650 nm
    Power supply voltage   10–30 VDC, including 10% (p-p) ripple, Class 2 or LPS
    Power consumption   24V/60mA
    Control output  

    NPN collector open-circuit

    The applied voltage is below 30 VDC,

    The control current is below 100 mA,

    When the residual voltage is below 10 mA, it is below 1.2 V.

    Below 2V at currents from 10 to 100mA

    PNP collector open-circuit

    Control the current below 100 mA.

    Protection circuit   Power reverse connection protection, output overcurrent protection, output surge protection, output reverse connection protection
    Output action   Switching method: ON when light is detected / ON when light is blocked
    External input  

    Time tuning input: ON when greater than 35ms, OFF when greater than 35ms.

    Lighting stop: ON when over 2ms, OFF when over 20ms.

    Enclosure protection rating   IP65
    Ambient lighting   Incandescent lamps: below 2000 lux; daylight: below 4000 lux.
    Ambient temperature   -10 to +50°C (no freezing)
    Storage environment temperature   -25 to +75°C (no freezing)
    Relative humidity   35% to 85% RH (no condensation)
    Impact resistance   6 times each in the X, Y, and Z directions at 1000 m/s²
    Vibration resistance   10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y, and Z directions
    Timer   OFF/ON - Delay/OFF - Delay/Single Pulse
  •  

     

    Model: LS-D2-50A/LS-D2-50AP

     

     

     

     

Keywords:

Sensor

Measurement sensor

Measuring instrument

Visual system

Communication

Product Inquiry